Electronic active energy meters with LCD display
by EMH
Type designation:
Electricity meters with LON-BUS
to measure positive and optional negative active energy. In single or two collective version. Space-saving mounting due to compact design.
The direct measurement of the execution is following 3 - or 4 - phase busbars
prepared.
Controls and displays
- 8 digit LCD display, including 3 decimal places, digit size: 4 x 6mm
- Mechanical button for ads calling
Parameterization
- Using LON-bus
- Locally adjustable CT ratio
Electrical characteristics
- Types of measurement active Energy, +A (with backstop), option: -A
- Energy counters max. 2 tariff register (T1 / T2) for each energy direction
- Secondary or primary impulse output
- Data retention in the absence of power at least 20 years in the EEPROM
Mechanical characteristics
- Snap-on housing (6M) 107,5 x 89,5 x 64,2mm, with fork busbar connection
- Connection screw-type terminals
current CT meter: 4mm²
current direct measurement meter: 16mm²
additional terminals: 2,5mm²
Approvals
- PTB-approval
- EC-type examination certificate according to Directive 2004/22/EC
(MID = Measuring Instrument Directive)
Options
- Battery for reading in the absence of power
- Calibration
Technical data:
- Type of construction:
snap-on housing 6M
107,5 x 89,5 x 64,2mm
- Degree of protection:
IP20
- Weight:
approx. 400g
- Climatic conditions:
ambient and
operating temperature: -25 to +55°C
storage temperature: -40 to +70°C
humidity: 95% not condensing
- Connection:
screw-type terminals
current CT meter: 4mm²
current direct measurement meter: 16mm²
additional terminals: 2,5mm²
- Display:
8 digit LCD display,
including 3 decimal places
digit size: 4 x 6mm
- Buttons:
for display call
- Energy counters:
max. 2 tariff register (T1 / T2) for each energy direction
- Current:
CT meter: 5||1 A / 1 (6) A
direct measurement meter: 5 (65) A
- Starting current:
CT meter: 2mA
direct measurement meter: 20mA
- Data retention in the absence of power:
at least 20 years in the EEPROM
- Types of measurement:
active Energy, +A (with backstop)
- Frequencies:
50Hz, 60Hz, 16,7Hz
- Voltage direct measurement meter:
4 wire-version: 3x290/500V; 3x230/400V; 3x63/110V; 3x58/100V
3 wire-version: 3x500V; 3x400V; 3x230V; 3x110V, 3x100V
2 wire-version: 230V, 110V, 100V; 63V; 58V
- Voltage CT meter:
4 wire-version: 3x290/500V; 3x230/400V
3 wire-version: 3x500V; 3x400V; 3x230V
2 wire-version: 230V
- Accuracy:
class 1 or class 2 according to IEC 62053-21
class B or A according to EN 50470-1,-3
- Power consumption per phase:
voltage path: < 2,0VA / 1,0W
current path direct measurement meter: < 2,5VA
current path CT meter: < 0,5 VA
- Transmission:
LON FTT10A two wire (twisted-pair),
78kbps, max. 2,7km
- Approvals:
PTB-approval
EC-type examination certificate according to directive 2004/22/EC (MID = Measuring Instrument Directive)
- Parameterization:
using LON-bus
- EMC, immunity of interference:
isolation: 4 kV AC, 50 Hz, 1 min
EMC: 4 kV, pulse 1,2/50 μs, 2 Ω
ISO: 6 kV, pulse 1,2/50 μs, 500 Ω10 V/m (under load)
subject to change