Overview MVE series




               General data:     Creepage distances: UNITRO-Standard
                                 Degree of protection: IP20
                                 Climatic conditions: UNITRO-Standard
                                 EMC-values: UNITRO-Standard
                                 Status indicating with LEDs
                                 Transparent cover with transparent technology


              Type     MVE 8/0   MVE16/0   MVE 0/8(-H)   MVE0/16   MVE 8/8   MVE 0/3w   MVE 0/6w   MVE 8/3w   MVE 0/3w8s   MVE 8/8-L   MVE 0/8-E
              Function                                                                               (0/8)
                      8x digital    16x digital    8x digital    16x digital    8x digital In-   3x digital   6x digital   8x digital In-  3x digital      8x digital
                      Inputs   Inputs   Outputs   Outputs   and Outputs   Outputs   Outputs   puts    Outputs   8x digital In-  Outputs
                                                                change-over   change-over   3x dig Out-  change-over   puts and or
                                                                                  puts change-  8x digital   8x Outputs   (max.
                                                                                  over    Outputs nor-  change-over   8x 6 EVGs)
                                                                                          mally open
              Dimen-
              sions   100x75x85   100x75x85   100x75x85   100x75x85   100x75x85   100x75x85   100x75x85   100x75x85   100x75x85   150x75x60   150x75x60
              in mm
              Weight ap-  270g   300g    270g     300g    300g     270g    300g     300g    300g   520g (450 g)   520g
              prox.
              Connec-  Screw-type   Screw-type   Screw-type   Screw-type   Screw-type   Screw-type   Screw-type   Screw-type   Screw-type   Screw-type   Screw-type
              tion termi-  terminals/   terminals/   terminals/   terminals/   terminals/   terminals/   terminals/   terminals/   terminals/   terminals/   terminals/
              nals    plug    plug     plug    plug     plug    plug     plug     plug    plug     plug    plug
                      connection    connection    connection    connection    connection    connection    connection    connection    connection    connection    connection
                      max. 2,5mm²   max. 2,5mm²   max. 2,5mm²   max. 2,5mm²   max. 2,5mm²   max. 2,5mm²   max. 2,5mm²   max. 2,5mm²   max. 2,5mm²   max. 2,5mm²   max. 2,5mm²
              Power sup-  24V AC/DC   24V AC/DC   24V AC/DC   24V AC/DC   24V AC/DC   24V AC/DC   24V AC/DC   24V AC/DC   24V AC/DC   24V AC/DC   24V AC/DC
              ply     100mA,    100mA,    100mA,    100mA,    100mA,    100mA,    100mA,    100mA,    100mA,    120mA,    120mA,
                      ± 10% or    ± 10% or    ± 10% or    ± 10% or    ± 10% or    ± 10% or    ± 10% or    ± 10% or    ± 10% or 85-  ± 10% or    ± 10%
                      85-265VAC /   85-265VAC /   85-265VAC /   85-265VAC /   85-265VAC /   85-265VAC /   85-265VAC /   85-265VAC /   265VAC /   85-265VAC/
                      85-250VDC,   85-250VDC,   85-250VDC,   85-250VDC,   85-250VDC,   85-250VDC,   85-250VDC,   85-250VDC,   85-250VDC,   85-250VDC
                      100mA   100mA    100mA   100mA    100mA   100mA    100mA    100mA   100mA    6VA
              Isolated in-  24V AC/DC   24V AC/DC       24V AC/DC                 24V AC/DC        230VAC,
              puts                                                                                 3mA
                      or 230V AC   or 230V AC           or 230V AC                or 230V AC
                      7mA     7mA                       7mA                       7mA              24V AC/DC
                      2000Vrms   2000Vrms               2000Vrms                  2000Vrms         6mA
                                                                                                   2000Vrms
              Isolated                 Normally   Normally   Normally   Change-  Change-  Change-  Normally   Change-  Normally
              outputs                  open max.   open max.   open max.   over max.   over max.   over max.   open and   over max.   open max.
                                       250V AC, 5A   250V AC, 5A   250V AC, 5A   250V AC,5A    250V AC,5A    250V AC,5A    change-over  250V AC,   250V AC,
                                       25V DC, 5A   25V DC, 5A   25V DC, 5A   25V DC, 5A   25V DC, 5A   25V DC, 5A   max. 250V   16A    16A
                                       2000Vrms   2000Vrms   2000Vrms   2000Vrms   2000Vrms   2000Vrms   AC, 5A    2000Vrms   2000Vrms
                                                                                          25V DC, 5A
                                                                                          2000Vrms
              Neuron   3150 /   3150 /   3150 /   3150 /   3150 /   3150 /   3150 /   3150 /   3150 /   3150 /   3150 /
              chip    10MHz   10MHz    10MHz   10MHz    10MHz   10MHz    10MHz    10MHz   10MHz    10MHz   10MHz
              Memory
              capacity   64kB Flash   64kB Flash   64kB Flash   64kB Flash   64kB Flash   64kB Flash   64kB Flash   64kB Flash   64kB Flash   64kB Flash   64kB Flash
              Bus-Trans-
              ceiver   FTT 10A TP   FTT 10A TP   FTT 10A TP   FTT 10A TP   FTT 10A TP   FTT 10A TP   FTT 10A TP   FTT 10A TP   FTT 10A TP   FTT 10A TP   FTT 10A TP
              Special    Type add.   Type add.   Type add.   Type add.   Type add.         Type add.   Type add.   Outputs with   Outputs with
              functions   H:   H:      H:      H:       H:                        H:      H:       manual   manual
                      Inputs with   Inputs with   Outputs with   Outputs with   In- and out-  Inputs with   Outputs (nor-  emergency   emergency
                      manual   manual   manual   manual   puts with               manual   mally open)   switches   switches
                      emergency   emergency   emergency   emergency   manual      emergency   with manual   max. inrush   max. inrush
                      switches   switches   switches   switches   emergency       switches   emergency   current 80A,   current
                                                        switches                          switches   20ms   120A, 20ms
              Available   Metering                                                                 Switch Lamp
              software.   functions,                                                               Actuator sun-
              Standard   Timer                                                                     blind
              software   SNVT`s
              packages
              on the In-
              ternet







                                                      subject to change                                Page 106