Page 2 - LON-bus components
P. 2

Fleischmann




                                                                                 STÖRMELDESYSTEME
                                                           LON-bus Components
                      MVC/MVE-Series            MVL-Series               LM-Series              Special types

                Series

                     Snap-on modules for sub- Low priced snap-on modules
                                                                        DIN rail mounting
                        distribution cabinet   for subdistribution cabinet   Snap-on modules for
                       power supply + inputs max.   supply max. 230VAC inputs 24V   power supply + inputs max. 24V

                       8 IN   MVE 8/0         8 IN     MVL 8/0      16 IN      LM 16/0
                                      1)
                     16 IN   MVE16/0+H      24V or S0

                                                                    16 IN    LM 16/0-M
                       8 OUT   MVE 0/8        8 OUT                 16 IN    LM 16/0-S
                     16 OUT   MVE0/16+H     normally open   MVL 0/8
                                      1)
                     normally open
                                                                    16 OUT   LM 0/16R
                                                                     normally open
                       8 IN   MVE 8/8+H
                                     1)
                       8 OUT                  4 IN
                     normally open  MVE 0/3w   24V or S0   MVL 4/4   16 OUT   LM 0/16 mod1
                                              4 OUT
                                                                             LM 0/16 mod2

                                                                    16 OUT
                                            normally open
                      3w OUT

                             MVE 0/6w
                     change-over

                                                                      8 OUT
                                            24V or 230V
                                                                    normally open
                  digital I/O-Modules    6w OUT     MVE 8/3w+H      24 IN     MVL 24/0       8 IN     LM 8/8R

                      8 IN

                                      1)


                      3w OUT
                                                                    16 IN
                                                                             LM 16/8R

                     change-over

                                                                    normally open

                      3w OUT
                                                                    32 IN
                     Wechsler   MVE 0/3w8S                            8 OUT   LM 32/0-M
                                      1)
                      8S OUT                   +H                   32 IN    LM 32/0-S
                     normally open

                       8 OUT  MVE 0/8E                              32 OUT                  Three-phase active power me-
                     Last EVG  with emergency/Auto   Terminating resistor   opto mos   LM 0/32   ters and energy meters
                     normally open
                                                     MVL
                       8 IN   MVE 8/8L               TW             8 IN    LM 8/8R       FTT10A
                       8 OUT   with emergency/Auto                  8 OUT     PLT22
                     change-over                                    normally open

                     1) option with emergency switches
                                                                 FTT10A      8 IN/OUT  LM 8 ana GT     Weather Stations


                analog I/O-Modules                                  16 OUT     LM 0/16 ana





                                         FTT10A                       8 OUT     LM 0/8 ana


                                                                        8 IN/OUT  LM 8 ana GT
                                                                              PLT22

                                                      FTT 10A                            PLT22   FTT 10A
                Infrastructur   Modules                    LWL   Repeater
                       MPCC1      Router       Router                    Router         power        GPRS Router

                                               FTT/RS485
                                                                         FTT/PLT
                                  FTT/FTT
                                                                                        230/400V
                        TCP/IP                                                          coupler     DSL and GSM
                    Internet/Intranet   max. 2,7km      fibre optics        approx. 20km  approx. 5km   (RemoteManager)
                                                                  FTT 10A
                                         DCF           DCF
                Output   Systems
                       ME8-P     ME16-P       LED LON
                                               ME24-P
                                  LON
                       LON

                                                                                 C3text
                                                                                                  Data base
                     8 IN      16 IN        24 double LED       320 plain text messages   Printer   Visualizations
                     8 OUT     2x16 OUT      red / green                                          Binding
                                                           Overview of  all LON-bus components
            Page 101                                   subject to change
   1   2   3   4   5   6   7