Page 7 - UNITRO Alarm Annunciators
P. 7

Connection diagram FSB 16-LED














































            Technical data:
               1.   Type of construction:                      8.    Signal input voltage:
                    control board housing 96 x 96 x 85 + 25mm        48-220V DC     ±15%
                    (cutting for installation: 92 x 92 + 1mm)        voltage-adapted
                                                                     voltage tolerance ±10%
               2.   Degree of protection:
                    front IP50 (option IP54), rear IP20        9.    Rated current (signaling input):
                                                                     at 48V DC      0,5mA
               3.   Weight:                                          at 220V DC     1mA
                    approx. 250g
                                                               10.   Power loss 100% ED:
               4.   Climatically conditions:                         max. 10W
                    in accordance with UNITRO-Standard
                                                               11.   LED display:
               5.   Connection:                                      labeled with marking strips
                    screw-type terminals/ plug connection            alarm:            red steady light
                    max. 2,5mm²
                                                                     no alarm:         LED off
               6.   Front panel button:                              power on LED = green steady light
                    LED test
                                                               12.   Leakage distances and clearances:
               7.   Supply voltage:                                  in accordance with UNITRO-Standard
                    48-220V DC    ±15%                         13.   EMC, immunity of interference:
                    voltage-adapted
                                                                     UNITRO-Standard,
                                                                     in accordance with EN 61000