{"id":2551,"date":"2017-07-19T14:01:15","date_gmt":"2017-07-19T12:01:15","guid":{"rendered":"https:\/\/www.unitro.de\/wp\/me-8-p-logic\/"},"modified":"2021-10-12T14:11:10","modified_gmt":"2021-10-12T12:11:10","slug":"me-8-p-logic","status":"publish","type":"page","link":"https:\/\/www.unitro.de\/en\/products\/front-panel-installation-modules\/me-series\/me-8-p-logic\/","title":{"rendered":"ME 8-P logic"},"content":{"rendered":"\n<h1>\n\t\tME 8-P logic, integral logic annunciator\n\t<\/h1>\n<h4>\n\t\tControl board mounting &#8211; Fault indicating system\n\t<\/h4>\n\t\t\t<a href=\"https:\/\/www.unitro.de\/produktunterlagen\/fronteinbau\/ME\/ME_8-P_logic_engl.pdf\" target=\"_blank\" role=\"button\" rel=\"noopener\">\n\t\t\t\t\t\t\tData sheet as PDF\n\t\t\t\t\t<\/a>\n\t\t\t<a href=\"https:\/\/www.unitro.de\/en\/selection-by-function\/\" target=\"_self\" role=\"button\" rel=\"noopener\">\n\t\t\t\t\t\t\tback to the function criteria (Level 6)\n\t\t\t\t\t<\/a>\n\t\t\t<a href=\"https:\/\/www.unitro.de\/en\/selection-according-to-design\/\" target=\"_self\" role=\"button\" rel=\"noopener\">\n\t\t\t\t\t\t\tback to the design criteria\n\t\t\t\t\t<\/a>\n\t\t\t<a href=\"https:\/\/downloads.unitro.de\" target=\"_blank\" role=\"button\" rel=\"noopener\">\n\t\t\t\t\t\t\tDownloads for ME 8-P logic\n\t\t\t\t\t<\/a>\n\t<p><strong>Type designation:<\/strong><\/p>\n<strong>ME 8-P logic<\/strong><br \/>\n acknowledgeable new alert- flash warning\u00a0with 2 flashing frequencies <br \/>\n (ISA-18.1\/DIN 19235), with signal storage in case of power failure\u00a0for 8 messages, <br \/>\n <strong>parameterization via USB<\/strong>, <br \/>\n with logic-functions\n\t\t\t\t<a href=\"https:\/\/www.unitro.de\/en\/service-2\/emc-values\/\" target=\"_blank\" rel=\"noopener\" itemprop=\"url\">\n\t\t\t\t<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/05\/evu-standard-logo-engl.-2017-300x283.jpg\" alt=\"\" itemprop=\"image\" height=\"283\" width=\"300\" onerror=\"this.style.display='none'\"  \/>\n\t\t\t\t<\/a>\n\t\t\t\t<a href=\"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/05\/ME8P_01.jpg\" target=\"_self\" itemprop=\"url\" rel=\"noopener\">\n\t\t\t\t<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/05\/ME8P_01-1024x768.jpg\" alt=\"ME 8-P logic\" itemprop=\"image\" height=\"768\" width=\"1024\" title=\"ME 8-P logic\" onerror=\"this.style.display='none'\"  \/>\n\t\t\t\t<\/a>\n\t\t\t\t<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/06\/Text-Fallklappenrelais-engl-2-300x152.jpg\" alt=\"Text -Fallklappenrelais- engl-2\" itemprop=\"image\" height=\"152\" width=\"300\" title=\"Text -Fallklappenrelais- engl-2\" onerror=\"this.style.display='none'\"  \/>\n\t<p><strong>Controls and displays<\/strong><\/p>\n<ul>\n<li>Bright 5mm RGB-LED display<\/li>\n<li>Separate status indicator (green = Power ON \/ blue = USB connected)<\/li>\n<li>Easily exchangeable label strips<\/li>\n<li>Integrated mini horn and functional buttons<\/li>\n<\/ul>\n<p><strong>Parameterization<\/strong><\/p>\n<ul>\n<li>Integrated Mini USB interface for parameterization using Windows 7 Pro or higher<\/li>\n<li>Acknowledgeable new alert\/first alert flash warning,\u00a0all sequences ISA-18.1-1979 (R2004) and DIN 19235<\/li>\n<li>Quiescent \/ operating current &#8211; for each signal<\/li>\n<li>New alert \/ first alert &#8211; for each signal<\/li>\n<li>Inputs freely assignable to outputs for each signal<\/li>\n<li>Response delay variable for each signal from 50ms to 10min<br \/>\n (in steps of 50ms, 2s and 1min)<\/li>\n<li>Selectable LED colors (red\/green\/yellow\/blue\/white)<\/li>\n<li>Anti-tilt monitor<\/li>\n<\/ul>\n<p><strong>Electrical characteristics<\/strong><\/p>\n<ul>\n<li>8 signal inputs, common ground max. 230V AC \/ 240V DC\u00a0with filter switching and electrical isolation<\/li>\n<li>Resolution and switching precision \u2265 1ms<\/li>\n<li><a href=\"https:\/\/www.unitro.de\/en\/service-2\/emc-values\/\" target=\"_blank\" rel=\"noopener\">EMC-values: Higher immunity levels to UNITRO-PSC-Standard<\/a><\/li>\n<li>Potential-free outputs:<br \/>\n 2-pole contactless opto-mos switch max. 300V DC, 100mA (resolution \u22651ms) (projected),\u00a0<br \/>\n or normally open relay max. 5A 250V AC, 3A 30V DC (resolution \u226510 ms)<\/li>\n<li>Electrically isolated horn \/ test- and group signal output (max. 5A 250V AC, 3A 30V DC)<\/li>\n<li>States saved to memory on power failure<\/li>\n<\/ul>\n<p><strong>Mechanical characteristics<\/strong><\/p>\n<ul>\n<li>Compact plastic junction housing to IEC 61554 (72 x 144 x 160 + 25mm)<\/li>\n<li>Connection: Screw-type terminals or screw-type terminals, plug connection max. 2.5mm\u00b2<\/li>\n<\/ul>\n<h2>\n\t\tConnection diagram ME 8-P logic\n\t<\/h2>\n\t<p><strong>opto-mos<\/strong><\/p>\n\t\t\t\t<a href=\"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/05\/Anschlu\u00dfplan-ME8-P-Photo-OUT.jpg\" target=\"_self\" itemprop=\"url\" rel=\"noopener\">\n\t\t\t\t<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/05\/Anschlu\u00dfplan-ME8-P-Photo-OUT-1024x775.jpg\" alt=\"Anschlussplan ME 8-P logic Opto-mos\" itemprop=\"image\" height=\"775\" width=\"1024\" title=\"Anschlussplan ME 8-P logic Opto-mos\" onerror=\"this.style.display='none'\"  \/>\n\t\t\t\t<\/a>\n\t<p><strong>relay output 2-pole<\/strong><\/p>\n\t\t\t\t<a href=\"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/05\/Anschlu\u00dfplan-ME8-P-Relais-OUT.jpg\" target=\"_self\" itemprop=\"url\" rel=\"noopener\">\n\t\t\t\t<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/05\/Anschlu\u00dfplan-ME8-P-Relais-OUT-1024x775.jpg\" alt=\"Anschlusplan ME 8-P logic Relais-OUT\" itemprop=\"image\" height=\"775\" width=\"1024\" title=\"Anschlusplan ME 8-P logic Relais-OUT\" onerror=\"this.style.display='none'\"  \/>\n\t\t\t\t<\/a>\n\t<p><strong>Technical data:<\/strong><\/p>\n\t<ul>\n<li><strong>Type of construction:<br \/>\n<\/strong>control board housing 72 x 144 x 160 + 25mm<br \/>\n(cutting for installation 66 x 138 + 1mm)\n<hr \/>\n<\/li>\n<li><strong>Degree of protection:<br \/>\n<\/strong>front: IP50, with full-view\u00a0acrylic glass doors IP54<br \/>\nhousing: IP20\n<hr \/>\n<\/li>\n<li><strong>Weight:<br \/>\n<\/strong>max. 800g\n<hr \/>\n<\/li>\n<li><a href=\"https:\/\/www.unitro.de\/en\/service-2\/emc-values\/\" target=\"_blank\" rel=\"noopener\"><strong>Climatic conditions:<br \/>\n<\/strong>in accordance with UNITRO-PSC-Standard<\/a>\n<hr \/>\n<\/li>\n<li><strong>Connection:<br \/>\n<\/strong>screw-type terminal\/ plug-in connection <br \/>\nor plug connection terminals max. 2.5mm\u00b2\n<hr \/>\n<\/li>\n<li><strong>Supply voltage:<br \/>\n<\/strong>24V AC\/DC\u00a0<br \/>\n48-60V AC\/DC<br \/>\n110\/125V AC\/DC<br \/>\n220\/240V AC\/DC<br \/>\nvoltage-adapted\n<hr \/>\n<\/li>\n<li><strong>Alarm signal nominal voltage:<br \/>\n<\/strong>24V AC to 230V AC<br \/>\n24V DC to 240V DC<br \/>\nvoltage-adapted<br \/>\nvoltage tolerance \u00b110%\n<hr \/>\n<\/li>\n<li><strong>Input level for signal inputs:<br \/>\n<\/strong>at 24V AC \/ DC 8mA<br \/>\nat 230V AC 7mA<br \/>\nat 60V DC 4mA<br \/>\nat 110 \/ 125V DC 3mA<br \/>\nat 240V DC 2mA\n<hr \/>\n<\/li>\n<li><strong>Data retention in the absence of power:<br \/>\n<\/strong>20 years<\/li>\n<\/ul>\n\t<ul>\n<li><strong>Resolution:<br \/>\n<\/strong>\u2265 1ms (opto-mos)<br \/>\n\u2265 10ms (Relay)\n<hr \/>\n<\/li>\n<li><strong>Switch-on delay:<br \/>\n<\/strong>programmable from 50ms to 10min<br \/>\n(in steps of 50ms, 2s and 1min)\n<hr \/>\n<\/li>\n<li><strong>Minimum signal duration:<br \/>\n<\/strong>1ms\n<hr \/>\n<\/li>\n<li><strong>First-up discrimination:<br \/>\n<\/strong>1ms\n<hr \/>\n<\/li>\n<li><strong>Flashing frequencies:<br \/>\n<\/strong>2Hz \/ 0.5Hz\n<hr \/>\n<\/li>\n<li><strong>Power loss:<br \/>\n<\/strong>max. 6 W + 8x 0.5W\n<hr \/>\n<\/li>\n<li><strong>Relay outputs:<br \/>\n<\/strong>max. 5A 250V AC,\u00a0<br \/>\n3A 30V DC\n<hr \/>\n<\/li>\n<li><strong>Contactless signal outputs:<br \/>\n<\/strong>opto-mos switch max. 300V DC, 100mA\n<hr \/>\n<\/li>\n<li><strong>Parameterization interface:<br \/>\n<\/strong>Mini USB interface for parameterization\u00a0<br \/>\nwith software, used with Windows 7 Pro\u00a0or higher\n<hr \/>\n<\/li>\n<li><a href=\"https:\/\/www.unitro.de\/en\/service-2\/emc-values\/\" target=\"_blank\" rel=\"noopener\"><strong>Leakage distances and clearances:<br \/>\n<\/strong>in accordance with UNITRO-PSC-Standard<\/a>\n<hr \/>\n<\/li>\n<li><a href=\"https:\/\/www.unitro.de\/en\/service-2\/emc-values\/\" target=\"_blank\" rel=\"noopener\"><strong>EMC, immunity to interference:<br \/>\n<\/strong>UNITRO-PSC-Standard; immunity higher\u00a0<\/a><br \/>\n<a href=\"https:\/\/www.unitro.de\/en\/service-2\/emc-values\/\" target=\"_blank\" rel=\"noopener\">degrees of severity according to the\u00a0<\/a><br \/>\n<a href=\"https:\/\/www.unitro.de\/en\/service-2\/emc-values\/\" target=\"_blank\" rel=\"noopener\">actual generic standards DIN EN 61000<\/a><\/li>\n<\/ul>\n\t<p>subject to change<\/p>\n\n","protected":false},"excerpt":{"rendered":"<p>ME 8-P logic, integral logic annunciator Control board mounting &#8211; Fault indicating system Data sheet as PDF back to the function criteria (Level 6) back to the design criteria Downloads for ME 8-P logic Type designation: ME 8-P logic acknowledgeable new alert- flash warning\u00a0with 2 flashing frequencies (ISA-18.1\/DIN 19235), with signal storage in case of&hellip;<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":2582,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-2551","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>ME 8-P logic - UNITRO - Fleischmann St\u00f6rmeldesysteme<\/title>\n<meta name=\"description\" content=\"8 signal inputs, acknowledgeable new alert- flash warning, 2 flashing frequencies (ISA-18.1), signal storage in case of power failure, USB parameterization\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.unitro.de\/en\/products\/front-panel-installation-modules\/me-series\/me-8-p-logic\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ME 8-P logic - UNITRO - Fleischmann St\u00f6rmeldesysteme\" \/>\n<meta property=\"og:description\" content=\"8 signal inputs, acknowledgeable new alert- flash warning, 2 flashing frequencies (ISA-18.1), signal storage in case of power failure, USB parameterization\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.unitro.de\/en\/products\/front-panel-installation-modules\/me-series\/me-8-p-logic\/\" \/>\n<meta property=\"og:site_name\" content=\"UNITRO - Fleischmann St\u00f6rmeldesysteme\" \/>\n<meta property=\"article:modified_time\" content=\"2021-10-12T12:11:10+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/05\/evu-standard-logo-engl.-2017-300x283.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/products\\\/front-panel-installation-modules\\\/me-series\\\/me-8-p-logic\\\/\",\"url\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/products\\\/front-panel-installation-modules\\\/me-series\\\/me-8-p-logic\\\/\",\"name\":\"ME 8-P logic - UNITRO - Fleischmann St\u00f6rmeldesysteme\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/products\\\/front-panel-installation-modules\\\/me-series\\\/me-8-p-logic\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/products\\\/front-panel-installation-modules\\\/me-series\\\/me-8-p-logic\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.unitro.de\\\/wp-content\\\/uploads\\\/2017\\\/05\\\/evu-standard-logo-engl.-2017-300x283.jpg\",\"datePublished\":\"2017-07-19T12:01:15+00:00\",\"dateModified\":\"2021-10-12T12:11:10+00:00\",\"description\":\"8 signal inputs, acknowledgeable new alert- flash warning, 2 flashing frequencies (ISA-18.1), signal storage in case of power failure, USB parameterization\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/products\\\/front-panel-installation-modules\\\/me-series\\\/me-8-p-logic\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.unitro.de\\\/en\\\/products\\\/front-panel-installation-modules\\\/me-series\\\/me-8-p-logic\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/products\\\/front-panel-installation-modules\\\/me-series\\\/me-8-p-logic\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.unitro.de\\\/wp-content\\\/uploads\\\/2017\\\/05\\\/evu-standard-logo-engl.-2017-300x283.jpg\",\"contentUrl\":\"https:\\\/\\\/www.unitro.de\\\/wp-content\\\/uploads\\\/2017\\\/05\\\/evu-standard-logo-engl.-2017-300x283.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/products\\\/front-panel-installation-modules\\\/me-series\\\/me-8-p-logic\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/products\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Front panel-installation-modules\",\"item\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/products\\\/front-panel-installation-modules\\\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"ME-series\",\"item\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/products\\\/front-panel-installation-modules\\\/me-series\\\/\"},{\"@type\":\"ListItem\",\"position\":5,\"name\":\"ME 8-P logic\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/\",\"name\":\"UNITRO - Fleischmann St\u00f6rmeldesysteme\",\"description\":\"since 1977 the power to control\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/#organization\",\"name\":\"UNITRO - Fleischmann St\u00f6rmeldesysteme\",\"url\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.unitro.de\\\/wp-content\\\/uploads\\\/2017\\\/05\\\/unitro-logo.png\",\"contentUrl\":\"https:\\\/\\\/www.unitro.de\\\/wp-content\\\/uploads\\\/2017\\\/05\\\/unitro-logo.png\",\"width\":320,\"height\":100,\"caption\":\"UNITRO - Fleischmann St\u00f6rmeldesysteme\"},\"image\":{\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCJxURw1A7tEDsKUf81SRwnQ\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ME 8-P logic - UNITRO - Fleischmann St\u00f6rmeldesysteme","description":"8 signal inputs, acknowledgeable new alert- flash warning, 2 flashing frequencies (ISA-18.1), signal storage in case of power failure, USB parameterization","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.unitro.de\/en\/products\/front-panel-installation-modules\/me-series\/me-8-p-logic\/","og_locale":"en_US","og_type":"article","og_title":"ME 8-P logic - UNITRO - Fleischmann St\u00f6rmeldesysteme","og_description":"8 signal inputs, acknowledgeable new alert- flash warning, 2 flashing frequencies (ISA-18.1), signal storage in case of power failure, USB parameterization","og_url":"https:\/\/www.unitro.de\/en\/products\/front-panel-installation-modules\/me-series\/me-8-p-logic\/","og_site_name":"UNITRO - Fleischmann St\u00f6rmeldesysteme","article_modified_time":"2021-10-12T12:11:10+00:00","og_image":[{"url":"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/05\/evu-standard-logo-engl.-2017-300x283.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.unitro.de\/en\/products\/front-panel-installation-modules\/me-series\/me-8-p-logic\/","url":"https:\/\/www.unitro.de\/en\/products\/front-panel-installation-modules\/me-series\/me-8-p-logic\/","name":"ME 8-P logic - UNITRO - Fleischmann St\u00f6rmeldesysteme","isPartOf":{"@id":"https:\/\/www.unitro.de\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.unitro.de\/en\/products\/front-panel-installation-modules\/me-series\/me-8-p-logic\/#primaryimage"},"image":{"@id":"https:\/\/www.unitro.de\/en\/products\/front-panel-installation-modules\/me-series\/me-8-p-logic\/#primaryimage"},"thumbnailUrl":"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/05\/evu-standard-logo-engl.-2017-300x283.jpg","datePublished":"2017-07-19T12:01:15+00:00","dateModified":"2021-10-12T12:11:10+00:00","description":"8 signal inputs, acknowledgeable new alert- flash warning, 2 flashing frequencies (ISA-18.1), signal storage in case of power failure, USB parameterization","breadcrumb":{"@id":"https:\/\/www.unitro.de\/en\/products\/front-panel-installation-modules\/me-series\/me-8-p-logic\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.unitro.de\/en\/products\/front-panel-installation-modules\/me-series\/me-8-p-logic\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.unitro.de\/en\/products\/front-panel-installation-modules\/me-series\/me-8-p-logic\/#primaryimage","url":"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/05\/evu-standard-logo-engl.-2017-300x283.jpg","contentUrl":"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/05\/evu-standard-logo-engl.-2017-300x283.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/www.unitro.de\/en\/products\/front-panel-installation-modules\/me-series\/me-8-p-logic\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/www.unitro.de\/en\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/www.unitro.de\/en\/products\/"},{"@type":"ListItem","position":3,"name":"Front panel-installation-modules","item":"https:\/\/www.unitro.de\/en\/products\/front-panel-installation-modules\/"},{"@type":"ListItem","position":4,"name":"ME-series","item":"https:\/\/www.unitro.de\/en\/products\/front-panel-installation-modules\/me-series\/"},{"@type":"ListItem","position":5,"name":"ME 8-P logic"}]},{"@type":"WebSite","@id":"https:\/\/www.unitro.de\/en\/#website","url":"https:\/\/www.unitro.de\/en\/","name":"UNITRO - Fleischmann St\u00f6rmeldesysteme","description":"since 1977 the power to control","publisher":{"@id":"https:\/\/www.unitro.de\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.unitro.de\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.unitro.de\/en\/#organization","name":"UNITRO - Fleischmann St\u00f6rmeldesysteme","url":"https:\/\/www.unitro.de\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.unitro.de\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/05\/unitro-logo.png","contentUrl":"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/05\/unitro-logo.png","width":320,"height":100,"caption":"UNITRO - Fleischmann St\u00f6rmeldesysteme"},"image":{"@id":"https:\/\/www.unitro.de\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.youtube.com\/channel\/UCJxURw1A7tEDsKUf81SRwnQ"]}]}},"_links":{"self":[{"href":"https:\/\/www.unitro.de\/en\/wp-json\/wp\/v2\/pages\/2551","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.unitro.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.unitro.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.unitro.de\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.unitro.de\/en\/wp-json\/wp\/v2\/comments?post=2551"}],"version-history":[{"count":0,"href":"https:\/\/www.unitro.de\/en\/wp-json\/wp\/v2\/pages\/2551\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.unitro.de\/en\/wp-json\/wp\/v2\/pages\/2582"}],"wp:attachment":[{"href":"https:\/\/www.unitro.de\/en\/wp-json\/wp\/v2\/media?parent=2551"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}