{"id":2213,"date":"2017-07-12T12:17:20","date_gmt":"2017-07-12T10:17:20","guid":{"rendered":"https:\/\/www.unitro.de\/wp\/sissypro-first-value-annunciator-system\/"},"modified":"2017-12-01T15:51:52","modified_gmt":"2017-12-01T14:51:52","slug":"sissypro-first-value-annunciator-system","status":"publish","type":"page","link":"https:\/\/www.unitro.de\/en\/products\/scada-systems\/condition-facility-monitoring\/sissypro-first-value-annunciator-system\/","title":{"rendered":"SISSYpro First-Value Annunciator System"},"content":{"rendered":"<h1>\n\t\tSISSYpro first value annunciator system, with a resolution \u2265 1 ms<br \/>\n\t<\/h1>\n<h4>\n\t\tMessage detection chronologically for fast localization of the cause of the fault<br \/>\n\t<\/h4>\n<p>\t\t\t<a href=\"https:\/\/www.unitro.de\/produktunterlagen\/SISSYpro_mit_Unterstationen\/SISSYpro_engl.pdf\" target=\"_blank\" role=\"button\" rel=\"noopener\" ><br \/>\n\t\t\t\t\t\t\tData sheet as PDF<br \/>\n\t\t\t\t\t<\/a><br \/>\n\t\t\t<a href=\"https:\/\/downloads.unitro.de\" target=\"_blank\" role=\"button\" rel=\"noopener\" ><br \/>\n\t\t\t\t\t\t\tDownloads for SISSYpro<br \/>\n\t\t\t\t\t<\/a><br \/>\n\t\t\t\t<a href=\"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/07\/SISSYpro-Funktionstopologie-engl-ohne-Kopf.jpg\" target=\"_self\" itemprop=\"url\"><br \/>\n\t\t\t\t<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/07\/SISSYpro-Funktionstopologie-engl-ohne-Kopf-1024x599.jpg\" alt=\"SISSYpro Funktionstopologie engl ohne Kopf\" itemprop=\"image\" height=\"599\" width=\"1024\"  \/><br \/>\n\t\t\t\t<\/a><\/p>\n<h1>\n\t\tThe intelligent monitoring system SISSYpro per the initial value-fault indicator and data collection in the millisecond range:<br \/>\n\t<\/h1>\n<p>SISSYpro was originally designed specifically for the high demands of RUs area to monitor and enforce the electrical power supply. In addition to high EMC values a message detection \u2265 1ms was required regardless of the number of messages and also met for the first time from the beginning.<br \/>\n Through continuous development, with OPC Server and SQL cloud connectivity to SISSYpro has developed into an intelligent cyber-physical communication system towards industry 4.0.<\/p>\n<p>Particularly noteworthy is the wide and flexible needs of every system with high customer value in conjunc-tion with the various decentralized network capable of substations UNITRO which also as an HMI modules are highly outsourced autonomous intelligence.<br \/>\n These intelligent modules capture and store the messages with a real-time time stamp with a resolution of \u22651ms.<br \/>\n In a message log message then input message detection are transferred with message acknowledgment and elimination in chronological order in a real-time protocol to the control center and stored in a history list.<br \/>\n The autonomous intelligence of substations also guarantees reliable monitoring locally even when connec-tion problems to the control center, with storage of the data, even during a power failure and the possibility of then subsequent data transmission.<\/p>\n<p>The traffic with the field level takes place via the fully transparent LON network via 2-wire, fiber optic, power-line, or LON over IP (DSL \/ GPRS) with remote parameterization. This remote programming also includes the text creation or amendment and the voice input to the respective substations.<\/p>\n<p>Next are tools for remote maintenance such as TeamViewer, VNC etc. available.<br \/>\n On the expenditure side, a visualization enables visual communication. The Page Control package allows external communication via SMS, email, fax, and voice.<\/p>\n<p>The central SISSYpro server in the control room can be expanded by client sub centers. Data exchange takes place via TCP \/ IP, so that the data collection and analysis for the server \/ client principle over a LAN to any number of PCs and \/ or tablets can be distributed.\u00a0<\/p>\n<p><strong>The following are available as sub-stations:<\/strong><\/p>\n<ul>\n<li><a href=\"https:\/\/www.unitro.de\/en\/chronologicalalarmsystem-zfm-2378\/\"><strong>ZFM 2378<\/strong>: 19 &#8220;rack system for max. 512 messages with LED display<\/a><\/li>\n<li><a href=\"https:\/\/www.unitro.de\/en\/products\/scada-systems\/condition-facility-monitoring\/fme-32-w-19-input-card-for-zfm\/\"><strong>FME 32 W:<\/strong> 19 &#8220;plug-in card 6U, 20M, 32 Binary inputs with millisecond resolution and <strong>light field displays<\/strong><\/a><\/li>\n<li><a href=\"https:\/\/www.unitro.de\/en\/products\/c3-series\/c3-lon-bus-coupler\/\"><strong>C3:<\/strong> DIN rail remote control system, Network ready (FT and PL)<\/a><\/li>\n<li><a href=\"https:\/\/www.unitro.de\/en\/products\/front-panel-installation-modules\/me-series\/me-16-p-logic\/\"><strong>ME16-P logic:<\/strong> Front installation fault indicator for 16 messages<\/a><\/li>\n<li><a href=\"https:\/\/www.unitro.de\/en\/products\/front-panel-installation-modules\/wa\/\"><strong>WindowsAnnunciator (WA):<\/strong> front mounting fault indicators with RGB display area\u00a0for max. 200 messages<\/a><\/li>\n<li><a href=\"https:\/\/www.unitro.de\/en\/products\/c3-series\/c3text\/\"><strong>C3text:<\/strong> Front mounting plain text message system for 320 messages<\/a><\/li>\n<li>The integration of external <strong>PLC systems<\/strong> is also possible via an OPC client.<\/li>\n<\/ul>\n<p>Through this universal and flexible options of the various sub-stations, the system has found the RU field addition in industry, as in the automotive industry, in large refineries and in the communal area a wide suc-cessful deployment.<br \/>\n Also in the facility area and the logistics allow different communications media and infrastructure coupled with the self-sufficient substations connecting and networking globally distributed property.<br \/>\n In all these areas can be achieved through effective monitoring, in particular in energy and utility facilities to increase the availability and reduce downtime of plant and equipment.<br \/>\n Overall, the system can SISSYpro by its complex and intelligent hardware and software components with a continuous vertical and horizontal networking, be assigned as a modern communication system of the group of cyber-physical systems.<\/p>\n<p style=\"text-align: center;\">subject to change<\/p>\n","protected":false},"excerpt":{"rendered":"<p>SISSYpro first value annunciator system, with a resolution \u2265 1 ms Message detection chronologically for fast localization of the cause of the fault Data sheet as PDF Downloads for SISSYpro The intelligent monitoring system SISSYpro per the initial value-fault indicator and data collection in the millisecond range: SISSYpro was originally designed specifically for the high&hellip;<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":2709,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-2213","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>SISSYpro First-Value Annunciator System - UNITRO - Fleischmann St\u00f6rmeldesysteme<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.unitro.de\/en\/products\/scada-systems\/condition-facility-monitoring\/sissypro-first-value-annunciator-system\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"SISSYpro First-Value Annunciator System - UNITRO - Fleischmann St\u00f6rmeldesysteme\" \/>\n<meta property=\"og:description\" content=\"SISSYpro first value annunciator system, with a resolution \u2265 1 ms Message detection chronologically for fast localization of the cause of the fault Data sheet as PDF Downloads for SISSYpro The intelligent monitoring system SISSYpro per the initial value-fault indicator and data collection in the millisecond range: SISSYpro was originally designed specifically for the high&hellip;\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.unitro.de\/en\/products\/scada-systems\/condition-facility-monitoring\/sissypro-first-value-annunciator-system\/\" \/>\n<meta property=\"og:site_name\" content=\"UNITRO - Fleischmann St\u00f6rmeldesysteme\" \/>\n<meta property=\"article:modified_time\" content=\"2017-12-01T14:51:52+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/07\/SISSYpro-Funktionstopologie-engl-ohne-Kopf-1024x599.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/products\\\/scada-systems\\\/condition-facility-monitoring\\\/sissypro-first-value-annunciator-system\\\/\",\"url\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/products\\\/scada-systems\\\/condition-facility-monitoring\\\/sissypro-first-value-annunciator-system\\\/\",\"name\":\"SISSYpro First-Value Annunciator System - UNITRO - Fleischmann St\u00f6rmeldesysteme\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/products\\\/scada-systems\\\/condition-facility-monitoring\\\/sissypro-first-value-annunciator-system\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/products\\\/scada-systems\\\/condition-facility-monitoring\\\/sissypro-first-value-annunciator-system\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.unitro.de\\\/wp-content\\\/uploads\\\/2017\\\/07\\\/SISSYpro-Funktionstopologie-engl-ohne-Kopf-1024x599.jpg\",\"datePublished\":\"2017-07-12T10:17:20+00:00\",\"dateModified\":\"2017-12-01T14:51:52+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/products\\\/scada-systems\\\/condition-facility-monitoring\\\/sissypro-first-value-annunciator-system\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.unitro.de\\\/en\\\/products\\\/scada-systems\\\/condition-facility-monitoring\\\/sissypro-first-value-annunciator-system\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/products\\\/scada-systems\\\/condition-facility-monitoring\\\/sissypro-first-value-annunciator-system\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.unitro.de\\\/wp-content\\\/uploads\\\/2017\\\/07\\\/SISSYpro-Funktionstopologie-engl-ohne-Kopf-1024x599.jpg\",\"contentUrl\":\"https:\\\/\\\/www.unitro.de\\\/wp-content\\\/uploads\\\/2017\\\/07\\\/SISSYpro-Funktionstopologie-engl-ohne-Kopf-1024x599.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/products\\\/scada-systems\\\/condition-facility-monitoring\\\/sissypro-first-value-annunciator-system\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/products\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"SCADA systems\",\"item\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/products\\\/scada-systems\\\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Condition + Facility &#8211; Monitoring\",\"item\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/products\\\/scada-systems\\\/condition-facility-monitoring\\\/\"},{\"@type\":\"ListItem\",\"position\":5,\"name\":\"SISSYpro First-Value Annunciator System\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/\",\"name\":\"UNITRO - Fleischmann St\u00f6rmeldesysteme\",\"description\":\"since 1977 the power to control\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/#organization\",\"name\":\"UNITRO - Fleischmann St\u00f6rmeldesysteme\",\"url\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.unitro.de\\\/wp-content\\\/uploads\\\/2017\\\/05\\\/unitro-logo.png\",\"contentUrl\":\"https:\\\/\\\/www.unitro.de\\\/wp-content\\\/uploads\\\/2017\\\/05\\\/unitro-logo.png\",\"width\":320,\"height\":100,\"caption\":\"UNITRO - Fleischmann St\u00f6rmeldesysteme\"},\"image\":{\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCJxURw1A7tEDsKUf81SRwnQ\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"SISSYpro First-Value Annunciator System - UNITRO - Fleischmann St\u00f6rmeldesysteme","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.unitro.de\/en\/products\/scada-systems\/condition-facility-monitoring\/sissypro-first-value-annunciator-system\/","og_locale":"en_US","og_type":"article","og_title":"SISSYpro First-Value Annunciator System - UNITRO - Fleischmann St\u00f6rmeldesysteme","og_description":"SISSYpro first value annunciator system, with a resolution \u2265 1 ms Message detection chronologically for fast localization of the cause of the fault Data sheet as PDF Downloads for SISSYpro The intelligent monitoring system SISSYpro per the initial value-fault indicator and data collection in the millisecond range: SISSYpro was originally designed specifically for the high&hellip;","og_url":"https:\/\/www.unitro.de\/en\/products\/scada-systems\/condition-facility-monitoring\/sissypro-first-value-annunciator-system\/","og_site_name":"UNITRO - Fleischmann St\u00f6rmeldesysteme","article_modified_time":"2017-12-01T14:51:52+00:00","og_image":[{"url":"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/07\/SISSYpro-Funktionstopologie-engl-ohne-Kopf-1024x599.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.unitro.de\/en\/products\/scada-systems\/condition-facility-monitoring\/sissypro-first-value-annunciator-system\/","url":"https:\/\/www.unitro.de\/en\/products\/scada-systems\/condition-facility-monitoring\/sissypro-first-value-annunciator-system\/","name":"SISSYpro First-Value Annunciator System - UNITRO - Fleischmann St\u00f6rmeldesysteme","isPartOf":{"@id":"https:\/\/www.unitro.de\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.unitro.de\/en\/products\/scada-systems\/condition-facility-monitoring\/sissypro-first-value-annunciator-system\/#primaryimage"},"image":{"@id":"https:\/\/www.unitro.de\/en\/products\/scada-systems\/condition-facility-monitoring\/sissypro-first-value-annunciator-system\/#primaryimage"},"thumbnailUrl":"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/07\/SISSYpro-Funktionstopologie-engl-ohne-Kopf-1024x599.jpg","datePublished":"2017-07-12T10:17:20+00:00","dateModified":"2017-12-01T14:51:52+00:00","breadcrumb":{"@id":"https:\/\/www.unitro.de\/en\/products\/scada-systems\/condition-facility-monitoring\/sissypro-first-value-annunciator-system\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.unitro.de\/en\/products\/scada-systems\/condition-facility-monitoring\/sissypro-first-value-annunciator-system\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.unitro.de\/en\/products\/scada-systems\/condition-facility-monitoring\/sissypro-first-value-annunciator-system\/#primaryimage","url":"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/07\/SISSYpro-Funktionstopologie-engl-ohne-Kopf-1024x599.jpg","contentUrl":"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/07\/SISSYpro-Funktionstopologie-engl-ohne-Kopf-1024x599.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/www.unitro.de\/en\/products\/scada-systems\/condition-facility-monitoring\/sissypro-first-value-annunciator-system\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/www.unitro.de\/en\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/www.unitro.de\/en\/products\/"},{"@type":"ListItem","position":3,"name":"SCADA systems","item":"https:\/\/www.unitro.de\/en\/products\/scada-systems\/"},{"@type":"ListItem","position":4,"name":"Condition + Facility &#8211; Monitoring","item":"https:\/\/www.unitro.de\/en\/products\/scada-systems\/condition-facility-monitoring\/"},{"@type":"ListItem","position":5,"name":"SISSYpro First-Value Annunciator System"}]},{"@type":"WebSite","@id":"https:\/\/www.unitro.de\/en\/#website","url":"https:\/\/www.unitro.de\/en\/","name":"UNITRO - Fleischmann St\u00f6rmeldesysteme","description":"since 1977 the power to control","publisher":{"@id":"https:\/\/www.unitro.de\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.unitro.de\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.unitro.de\/en\/#organization","name":"UNITRO - Fleischmann St\u00f6rmeldesysteme","url":"https:\/\/www.unitro.de\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.unitro.de\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/05\/unitro-logo.png","contentUrl":"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/05\/unitro-logo.png","width":320,"height":100,"caption":"UNITRO - Fleischmann St\u00f6rmeldesysteme"},"image":{"@id":"https:\/\/www.unitro.de\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.youtube.com\/channel\/UCJxURw1A7tEDsKUf81SRwnQ"]}]}},"_links":{"self":[{"href":"https:\/\/www.unitro.de\/en\/wp-json\/wp\/v2\/pages\/2213","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.unitro.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.unitro.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.unitro.de\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.unitro.de\/en\/wp-json\/wp\/v2\/comments?post=2213"}],"version-history":[{"count":0,"href":"https:\/\/www.unitro.de\/en\/wp-json\/wp\/v2\/pages\/2213\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.unitro.de\/en\/wp-json\/wp\/v2\/pages\/2709"}],"wp:attachment":[{"href":"https:\/\/www.unitro.de\/en\/wp-json\/wp\/v2\/media?parent=2213"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}