{"id":2204,"date":"2017-07-12T11:25:10","date_gmt":"2017-07-12T09:25:10","guid":{"rendered":"https:\/\/www.unitro.de\/wp\/chronologicalalarmsystem-zfm-2378\/"},"modified":"2021-02-16T17:57:36","modified_gmt":"2021-02-16T16:57:36","slug":"chronologicalalarmsystem-zfm-2378","status":"publish","type":"page","link":"https:\/\/www.unitro.de\/en\/products\/scada-systems\/condition-facility-monitoring\/chronologicalalarmsystem-zfm-2378\/","title":{"rendered":"ChronologicalAlarmSystem (ZFM 2378)"},"content":{"rendered":"\n<h1>\n\t\tChronologicalAlarmSystem (ZFM 2378)\n\t<\/h1>\n<h4>\n\t\tStand-alone or SISSYpro substation\n\t<\/h4>\n\t\t\t<a href=\"https:\/\/www.unitro.de\/produktunterlagen\/ZFM_FME\/ZFM_engl.pdf\" target=\"_blank\" role=\"button\" rel=\"noopener\">\n\t\t\t\t\t\t\tData sheet as PDF\n\t\t\t\t\t<\/a>\n\t\t\t<a href=\"https:\/\/downloads.unitro.de\" target=\"_blank\" role=\"button\" rel=\"noopener\">\n\t\t\t\t\t\t\tDownloads for ZFM\n\t\t\t\t\t<\/a>\n\t\n<strong>ZFM 2378<\/strong><br \/>\nchronological reporting system<br \/>\n max. 512 messages and a<br \/>\n resolution of up to \u2265 1ms,<br \/>\n according to ISA-18.1 \/ DIN 19235,<br \/>\n configurable via USB interface<br \/>\n or remote programming <br \/>\n by SISSYpro<strong><br \/>\n <\/strong>\n\t\t\t\t<a href=\"https:\/\/www.unitro.de\/en\/service-2\/emc-values\/\" target=\"_blank\" rel=\"noopener\" itemprop=\"url\">\n\t\t\t\t<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/05\/evu-standard-logo-engl.-2017-300x283.jpg\" alt=\"\" itemprop=\"image\" height=\"283\" width=\"300\" onerror=\"this.style.display='none'\"  \/>\n\t\t\t\t<\/a>\n\t\t\t\t<a href=\"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/06\/19Zoll_Einbau.jpg\" target=\"_self\" itemprop=\"url\" rel=\"noopener\">\n\t\t\t\t<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/06\/19Zoll_Einbau-1024x683.jpg\" alt=\"Foto zeigt ZFM mit FME 32\" itemprop=\"image\" height=\"683\" width=\"1024\" title=\"Bild 017\" onerror=\"this.style.display='none'\"  \/>\n\t\t\t\t<\/a>\n\tPhoto shows ZFM with FME 32 C<strong><br \/>\n <\/strong>\n\t\n<ul>\n<li>For maximum 224 messages: installation 19 &#8220;rack system 3x 6U (depth 270mm) for:<br \/> <strong>1x power supply card<\/strong> 3U 6M with <strong>power outage notification<\/strong>, <br \/> <strong>1x CPU<\/strong> 2378, 6U 4M and<br \/> <a href=\"https:\/\/www.unitro.de\/en\/products\/scada-systems\/condition-facility-monitoring\/fme-32-w-19-input-card-for-zfm\/\"><strong>7x input cards FME 32 W<\/strong><\/a>, 32 per message, 6U 20M\u00a0<br \/> (24V DC \/ 60V DC \/ 110V DC \/ 220V DC labeled with 10 x 32mm <strong>light field displays<\/strong>)<\/li>\n<li>For maximum <strong>512 messages<\/strong>: installation 19 &#8220;rack system 1x 6U (depth 270mm) for:<br \/> <strong>1x power supply card<\/strong> 3U 6M with <strong>power outage notification<\/strong>, <br \/> <strong>1x CPU<\/strong> 2378, 6U 4M and<br \/> <strong>16x input cards EK32<\/strong>, 32 per message, 3U 4M\u00a0<br \/> (24V DC \/ 60V DC \/ 110V DC \/ 220V DC with LED display)<\/li>\n<\/ul>\n\n<ul>\n<li>On the CPU: <br \/> 1x USB (for parameterization using an external PC) <br \/> 1x RS 485 2x RS 232 (e.g. for printer) <br \/> 1x LON FTX <br \/> <strong>16x relay outputs<\/strong> change-over max. 125V 0.4A<\/li>\n<li>Connection: rear mounted edge-socket connector 32-pin wrap DIN 41612 mounting form D, <br \/> colour-coded connection line 32x 0,25mm\u00b2<\/li>\n<li>DCF77 radio clock or just optional GPS Clock to synchronize to 1ms<\/li>\n<\/ul>\n\n<ul>\n<li>via integrated <strong>USB interface<\/strong> or <strong>remote parameterization<\/strong> by SISSYpro:<br \/> cleartext logging with entering the plaintexts, q<strong>uiescent \/ operating current,\u00a0debounce time<\/strong> on the time scale of milliseconds, <strong>switch-on delay<\/strong> and <strong>flutter-signal handling<\/strong> on the time scale of seconds<\/li>\n<\/ul>\n\n<ul>\n<li>CPU 2378 processor card with time logical message storage<\/li>\n<li>Time synchronization of the SISSYpro control center or via built-in GPS \/ DCF clock<\/li>\n<li>Logging with date and time in ms resolution with 80 characters per message<\/li>\n<li><a href=\"https:\/\/www.unitro.de\/en\/service-2\/emc-values\/\" target=\"_blank\" rel=\"noopener\">EMC-values: Higher immunity levels to UNITRO-PSC-Standard<\/a><\/li>\n<\/ul>\n\n<ul>\n<li>Built-in printer<\/li>\n<\/ul>\n\t\t\t\t<a href=\"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/06\/ZFM-400-dpi-NWS.jpg\" target=\"_self\" itemprop=\"url\" rel=\"noopener\">\n\t\t\t\t<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/06\/ZFM-400-dpi-NWS-1024x814.jpg\" alt=\"ZFM (400 dpi) NWS\" itemprop=\"image\" height=\"814\" width=\"1024\" title=\"ZFM (400 dpi) NWS\" onerror=\"this.style.display='none'\"  \/>\n\t\t\t\t<\/a>\n\t<p>Photo shows ZFM with FME 32<\/p>\n<p>&nbsp;<\/p>\n\t\n\t<ul>\n<li><strong>Type of construction:<\/strong><br \/>\n19&#8243; rack mounting, 84M, 3U,\u00a0<br \/>\nmounting depth 270mm\n<hr \/>\n<\/li>\n<li><strong>Degree of protection:<\/strong><br \/>\nIP20\n<hr \/>\n<\/li>\n<li><strong>Weight:<\/strong><br \/>\napprox. 7kg,\u00a0<br \/>\ndepending on equipment variant\n<hr \/>\n<\/li>\n<li><a href=\"https:\/\/www.unitro.de\/en\/service-2\/emc-values\/\" target=\"_blank\" rel=\"noopener\"><strong>Climatic conditions:<\/strong><\/a><br \/>\n<a href=\"https:\/\/www.unitro.de\/en\/service-2\/emc-values\/\" target=\"_blank\" rel=\"noopener\">in accordance with\u00a0UNITRO-PSC-Standard<\/a>\n<hr \/>\n<\/li>\n<li><strong>Connection:<\/strong><br \/>\nrear mounted edge-socket connector 32-pin wrap <br \/>\nDIN 41612 mounting form D, <br \/>\ncolour-coded connection line\u00a032x 0,25mm\u00b2\n<hr \/>\n<\/li>\n<li>Supply voltages:<br \/>\n24V DC\u00a0\u00b1 10%<br \/>\n48-60V DC\u00a0\u00b1 10%<br \/>\n110\/125V DC\u00a0\u00b1 10%<br \/>\n220\/240V DC\u00a0\u00b1 10%<br \/>\n230V AC \u00b1 10%<br \/>\nvoltage-adapted\n<hr \/>\n<\/li>\n<li><strong>Inputs (plug-in cards):<\/strong><br \/>\nEK32: 3U 4M, 16 channels<br \/>\nFME 32: 6U 20M, channels<br \/>\n24V DC<br \/>\n60V DC<br \/>\n110V DC<br \/>\n220V DC\u00a0<br \/>\nvoltage-adapted<br \/>\nvoltage tolerance \u00b110%\n<hr \/>\n<\/li>\n<li><strong>Resolution \/ query cycle:<\/strong><br \/>\n1ms to 10ms,\u00a0depending on the configuration\n<hr \/>\n<\/li>\n<li><strong>Stages of development:<\/strong><br \/>\nfrom 16 to max. 512 messages<\/li>\n<\/ul>\n\t<ul>\n<li><strong>Transmission:<\/strong><br \/>\nLON FTT10A two wire (twisted-pair),<br \/>\n78kbps, max. 2,7km\n<hr \/>\n<\/li>\n<li>Bus connection:<br \/>\nisolated transceiver, 500V disconnecting\u00a0insulation voltage\n<hr \/>\n<\/li>\n<li><strong>Group-signal outputs:<\/strong><br \/>\noptional expandable to 256 outputs\n<hr \/>\n<\/li>\n<li><strong>Interfaces:<\/strong><br \/>\n1x USB (for programming using an external PC)\u00a0<br \/>\n1x RS485, 2x RS 232 ports (e.g. for printer)\u00a0<br \/>\n1x LON FTX,\u00a0<br \/>\n<strong>16x relay outputs<\/strong> change-over max. 125V 0,4A\n<hr \/>\n<\/li>\n<li><strong>System features:<\/strong><br \/>\n&#8211; DCF77 radio clock or just optional GPS clock to synchronize to 1ms<br \/>\n&#8211; or Time synchronization of the SISSYpro\u00a0control center<br \/>\n&#8211; logging with date and time in ms resolution<br \/>\n&#8211; 80 characters per message<br \/>\n&#8211; selectable for quiescent \/ operating current\u00a0per message<br \/>\n&#8211; plain text logging, entering the full text with\u00a0PC<br \/>\n&#8211; debounce time on the time scale of\u00a0milliseconds<br \/>\n&#8211; switch-on delay on the time scale of seconds<br \/>\n&#8211; flutter-signal handling on the time scale of seconds\n<hr \/>\n<\/li>\n<li><a href=\"https:\/\/www.unitro.de\/en\/service-2\/emc-values\/\" target=\"_blank\" rel=\"noopener\"><strong>Leakage distances and clearances:<\/strong><\/a><br \/>\n<a href=\"https:\/\/www.unitro.de\/en\/service-2\/emc-values\/\" target=\"_blank\" rel=\"noopener\">in accordance with UNITRO-PSC-Standard<\/a>\n<hr \/>\n<\/li>\n<li><a href=\"https:\/\/www.unitro.de\/en\/service-2\/emc-values\/\" target=\"_blank\" rel=\"noopener\"><strong>EMC, immunity to interference:<\/strong><\/a><br \/>\n<a href=\"https:\/\/www.unitro.de\/en\/service-2\/emc-values\/\" target=\"_blank\" rel=\"noopener\">UNITRO-PSC-Standard,\u00a0<\/a><br \/>\n<a href=\"https:\/\/www.unitro.de\/en\/service-2\/emc-values\/\" target=\"_blank\" rel=\"noopener\">immunity higher degrees of severity <\/a><br \/>\n<a href=\"https:\/\/www.unitro.de\/en\/service-2\/emc-values\/\" target=\"_blank\" rel=\"noopener\">according to the actual generic standards DIN EN 61000<\/a><\/li>\n<\/ul>\n\t<p>subject to change<\/p>\n\n","protected":false},"excerpt":{"rendered":"<p>ChronologicalAlarmSystem (ZFM 2378) Stand-alone or SISSYpro substation Data sheet as PDF Downloads for ZFM ZFM 2378 chronological reporting system max. 512 messages and a resolution of up to \u2265 1ms, according to ISA-18.1 \/ DIN 19235, configurable via USB interface or remote programming by SISSYpro Photo shows ZFM with FME 32 C For maximum 224&hellip;<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":2709,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-2204","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>ChronologicalAlarmSystem (ZFM 2378) - UNITRO - Fleischmann St\u00f6rmeldesysteme<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.unitro.de\/en\/products\/scada-systems\/condition-facility-monitoring\/chronologicalalarmsystem-zfm-2378\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ChronologicalAlarmSystem (ZFM 2378) - UNITRO - Fleischmann St\u00f6rmeldesysteme\" \/>\n<meta property=\"og:description\" content=\"ChronologicalAlarmSystem (ZFM 2378) Stand-alone or SISSYpro substation Data sheet as PDF Downloads for ZFM ZFM 2378 chronological reporting system max. 512 messages and a resolution of up to \u2265 1ms, according to ISA-18.1 \/ DIN 19235, configurable via USB interface or remote programming by SISSYpro Photo shows ZFM with FME 32 C For maximum 224&hellip;\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.unitro.de\/en\/products\/scada-systems\/condition-facility-monitoring\/chronologicalalarmsystem-zfm-2378\/\" \/>\n<meta property=\"og:site_name\" content=\"UNITRO - Fleischmann St\u00f6rmeldesysteme\" \/>\n<meta property=\"article:modified_time\" content=\"2021-02-16T16:57:36+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/05\/evu-standard-logo-engl.-2017-300x283.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/products\\\/scada-systems\\\/condition-facility-monitoring\\\/chronologicalalarmsystem-zfm-2378\\\/\",\"url\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/products\\\/scada-systems\\\/condition-facility-monitoring\\\/chronologicalalarmsystem-zfm-2378\\\/\",\"name\":\"ChronologicalAlarmSystem (ZFM 2378) - UNITRO - Fleischmann St\u00f6rmeldesysteme\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/products\\\/scada-systems\\\/condition-facility-monitoring\\\/chronologicalalarmsystem-zfm-2378\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/products\\\/scada-systems\\\/condition-facility-monitoring\\\/chronologicalalarmsystem-zfm-2378\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.unitro.de\\\/wp-content\\\/uploads\\\/2017\\\/05\\\/evu-standard-logo-engl.-2017-300x283.jpg\",\"datePublished\":\"2017-07-12T09:25:10+00:00\",\"dateModified\":\"2021-02-16T16:57:36+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/products\\\/scada-systems\\\/condition-facility-monitoring\\\/chronologicalalarmsystem-zfm-2378\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.unitro.de\\\/en\\\/products\\\/scada-systems\\\/condition-facility-monitoring\\\/chronologicalalarmsystem-zfm-2378\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/products\\\/scada-systems\\\/condition-facility-monitoring\\\/chronologicalalarmsystem-zfm-2378\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.unitro.de\\\/wp-content\\\/uploads\\\/2017\\\/05\\\/evu-standard-logo-engl.-2017-300x283.jpg\",\"contentUrl\":\"https:\\\/\\\/www.unitro.de\\\/wp-content\\\/uploads\\\/2017\\\/05\\\/evu-standard-logo-engl.-2017-300x283.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/products\\\/scada-systems\\\/condition-facility-monitoring\\\/chronologicalalarmsystem-zfm-2378\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/products\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"SCADA systems\",\"item\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/products\\\/scada-systems\\\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Condition + Facility &#8211; Monitoring\",\"item\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/products\\\/scada-systems\\\/condition-facility-monitoring\\\/\"},{\"@type\":\"ListItem\",\"position\":5,\"name\":\"ChronologicalAlarmSystem (ZFM 2378)\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/\",\"name\":\"UNITRO - Fleischmann St\u00f6rmeldesysteme\",\"description\":\"since 1977 the power to control\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/#organization\",\"name\":\"UNITRO - Fleischmann St\u00f6rmeldesysteme\",\"url\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.unitro.de\\\/wp-content\\\/uploads\\\/2017\\\/05\\\/unitro-logo.png\",\"contentUrl\":\"https:\\\/\\\/www.unitro.de\\\/wp-content\\\/uploads\\\/2017\\\/05\\\/unitro-logo.png\",\"width\":320,\"height\":100,\"caption\":\"UNITRO - Fleischmann St\u00f6rmeldesysteme\"},\"image\":{\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCJxURw1A7tEDsKUf81SRwnQ\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ChronologicalAlarmSystem (ZFM 2378) - UNITRO - Fleischmann St\u00f6rmeldesysteme","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.unitro.de\/en\/products\/scada-systems\/condition-facility-monitoring\/chronologicalalarmsystem-zfm-2378\/","og_locale":"en_US","og_type":"article","og_title":"ChronologicalAlarmSystem (ZFM 2378) - UNITRO - Fleischmann St\u00f6rmeldesysteme","og_description":"ChronologicalAlarmSystem (ZFM 2378) Stand-alone or SISSYpro substation Data sheet as PDF Downloads for ZFM ZFM 2378 chronological reporting system max. 512 messages and a resolution of up to \u2265 1ms, according to ISA-18.1 \/ DIN 19235, configurable via USB interface or remote programming by SISSYpro Photo shows ZFM with FME 32 C For maximum 224&hellip;","og_url":"https:\/\/www.unitro.de\/en\/products\/scada-systems\/condition-facility-monitoring\/chronologicalalarmsystem-zfm-2378\/","og_site_name":"UNITRO - Fleischmann St\u00f6rmeldesysteme","article_modified_time":"2021-02-16T16:57:36+00:00","og_image":[{"url":"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/05\/evu-standard-logo-engl.-2017-300x283.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.unitro.de\/en\/products\/scada-systems\/condition-facility-monitoring\/chronologicalalarmsystem-zfm-2378\/","url":"https:\/\/www.unitro.de\/en\/products\/scada-systems\/condition-facility-monitoring\/chronologicalalarmsystem-zfm-2378\/","name":"ChronologicalAlarmSystem (ZFM 2378) - UNITRO - Fleischmann St\u00f6rmeldesysteme","isPartOf":{"@id":"https:\/\/www.unitro.de\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.unitro.de\/en\/products\/scada-systems\/condition-facility-monitoring\/chronologicalalarmsystem-zfm-2378\/#primaryimage"},"image":{"@id":"https:\/\/www.unitro.de\/en\/products\/scada-systems\/condition-facility-monitoring\/chronologicalalarmsystem-zfm-2378\/#primaryimage"},"thumbnailUrl":"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/05\/evu-standard-logo-engl.-2017-300x283.jpg","datePublished":"2017-07-12T09:25:10+00:00","dateModified":"2021-02-16T16:57:36+00:00","breadcrumb":{"@id":"https:\/\/www.unitro.de\/en\/products\/scada-systems\/condition-facility-monitoring\/chronologicalalarmsystem-zfm-2378\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.unitro.de\/en\/products\/scada-systems\/condition-facility-monitoring\/chronologicalalarmsystem-zfm-2378\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.unitro.de\/en\/products\/scada-systems\/condition-facility-monitoring\/chronologicalalarmsystem-zfm-2378\/#primaryimage","url":"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/05\/evu-standard-logo-engl.-2017-300x283.jpg","contentUrl":"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/05\/evu-standard-logo-engl.-2017-300x283.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/www.unitro.de\/en\/products\/scada-systems\/condition-facility-monitoring\/chronologicalalarmsystem-zfm-2378\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/www.unitro.de\/en\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/www.unitro.de\/en\/products\/"},{"@type":"ListItem","position":3,"name":"SCADA systems","item":"https:\/\/www.unitro.de\/en\/products\/scada-systems\/"},{"@type":"ListItem","position":4,"name":"Condition + Facility &#8211; Monitoring","item":"https:\/\/www.unitro.de\/en\/products\/scada-systems\/condition-facility-monitoring\/"},{"@type":"ListItem","position":5,"name":"ChronologicalAlarmSystem (ZFM 2378)"}]},{"@type":"WebSite","@id":"https:\/\/www.unitro.de\/en\/#website","url":"https:\/\/www.unitro.de\/en\/","name":"UNITRO - Fleischmann St\u00f6rmeldesysteme","description":"since 1977 the power to control","publisher":{"@id":"https:\/\/www.unitro.de\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.unitro.de\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.unitro.de\/en\/#organization","name":"UNITRO - Fleischmann St\u00f6rmeldesysteme","url":"https:\/\/www.unitro.de\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.unitro.de\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/05\/unitro-logo.png","contentUrl":"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/05\/unitro-logo.png","width":320,"height":100,"caption":"UNITRO - Fleischmann St\u00f6rmeldesysteme"},"image":{"@id":"https:\/\/www.unitro.de\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.youtube.com\/channel\/UCJxURw1A7tEDsKUf81SRwnQ"]}]}},"_links":{"self":[{"href":"https:\/\/www.unitro.de\/en\/wp-json\/wp\/v2\/pages\/2204","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.unitro.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.unitro.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.unitro.de\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.unitro.de\/en\/wp-json\/wp\/v2\/comments?post=2204"}],"version-history":[{"count":0,"href":"https:\/\/www.unitro.de\/en\/wp-json\/wp\/v2\/pages\/2204\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.unitro.de\/en\/wp-json\/wp\/v2\/pages\/2709"}],"wp:attachment":[{"href":"https:\/\/www.unitro.de\/en\/wp-json\/wp\/v2\/media?parent=2204"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}