{"id":2196,"date":"2017-07-11T17:03:19","date_gmt":"2017-07-11T15:03:19","guid":{"rendered":"https:\/\/www.unitro.de\/wp\/19-sissypro-substation-fme-32-c\/"},"modified":"2021-02-16T17:59:33","modified_gmt":"2021-02-16T16:59:33","slug":"fme-32-w-19-input-card-for-zfm","status":"publish","type":"page","link":"https:\/\/www.unitro.de\/en\/products\/scada-systems\/condition-facility-monitoring\/fme-32-w-19-input-card-for-zfm\/","title":{"rendered":"FME 32 W, 19&#8243; input card for ZFM"},"content":{"rendered":"\n<h1>\n\t\tFME 32 W\n\t<\/h1>\n<h4>\n\t\t<a href=\"https:\/\/www.unitro.de\/en\/products\/scada-systems\/condition-facility-monitoring\/chronologicalalarmsystem-zfm-2378\/\" title=\"19\" input card for ChronologicalAlarmSystem (ZFM)\" target=\"_self\">\n\t\t19&#8243; input card for ChronologicalAlarmSystem (ZFM)\n\t\t<\/a>\n\t<\/h4>\n\t\t\t<a href=\"https:\/\/unitro.de\/produktunterlagen\/ZFM_FME\/FME_32_W_engl.pdf\" target=\"_blank\" role=\"button\" rel=\"noopener\">\n\t\t\t\t\t\t\tData sheet as PDF\n\t\t\t\t\t<\/a>\n\t\t\t<a href=\"https:\/\/downloads.unitro.de\" target=\"_blank\" role=\"button\" rel=\"noopener\">\n\t\t\t\t\t\t\tDownloads for FME 32 W\n\t\t\t\t\t<\/a>\n\t\n<p><strong>FME 32 W<\/strong><br \/>signal logging of 32 binary inputs <br \/><strong>(light field displays)<\/strong><br \/>with millisecond resolution and <br \/>real-time assignment for SISSYpro<br \/>first-value annunciator system<br \/>according to ISA-18.1 \/ DIN 19235<\/p>\n\t\t\t\t<a href=\"https:\/\/www.unitro.de\/wp\/en\/service-2\/emc-values\/\" target=\"_blank\" rel=\"noopener\" itemprop=\"url\">\n\t\t\t\t<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/05\/evu-standard-logo-2017-300x283.jpg\" alt=\"EVU Standard\" itemprop=\"image\" height=\"283\" width=\"300\" title=\"EVU Standard\" onerror=\"this.style.display='none'\"  \/>\n\t\t\t\t<\/a>\n\t\t\t\t<a href=\"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/12\/FME-32-W-Beleuchtet.jpg\" target=\"_self\" itemprop=\"url\" rel=\"noopener\">\n\t\t\t\t<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/12\/FME-32-W-Beleuchtet-383x1024.jpg\" alt=\"FME 32 W (Beleuchtet)\" itemprop=\"image\" height=\"1024\" width=\"383\" title=\"FME 32 W (Beleuchtet)\" onerror=\"this.style.display='none'\"  \/>\n\t\t\t\t<\/a>\n\t\n<ul>\n<li>19&#8243; plug-in card 6U, 20M<\/li>\n<li>32 binary inputs with millisecond resolution and real-time mapping for SISSYpro first-value annunciator system<\/li>\n<li><strong>Parameterization<\/strong> about built-in <strong>USB port<\/strong> or <strong>remote programming<\/strong> via SISSYpro:<br \/> cleartext logging with entering the plaintexts, quiescent \/ operating current,\u00a0<strong>debounce time<\/strong> on the time scale of milliseconds, <br \/> <strong>switch-on delay<\/strong> and <strong>flutter-signal handling<\/strong> on the time scale of seconds<\/li>\n<li><strong>32 light field displays 10 x 32mm (selectable colors (red\/green\/yellow\/blue or white)<\/strong><br \/>with exchangeable marking strips flashing function in accordance with ISA-18.1 \/ DIN 19235, <br \/>with acknowledgment via integrated front button and remote acknowledgeable by the headquarters (SISSYpro)<\/li>\n<li>Time with millisecond time synchronization<\/li>\n<li>Message transmission to the control center<\/li>\n<li>Assumption of parameter data sets from the Central SISSYpro with fail-safe storagein EEPROM<\/li>\n<li><strong>Dead-man timer<\/strong> and watchdog for automatic reboot<\/li>\n<li><a href=\"https:\/\/www.unitro.de\/wp\/en\/service-2\/emc-values\/\" target=\"_blank\" rel=\"noopener\">EMC-values: Higher immunity levels to UNITRO-PSC-Standard<\/a><\/li>\n<\/ul>\n\t\t\t\t<a href=\"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/12\/FME-32-W-FME-32-C-Beleuchtet.jpg\" target=\"_self\" itemprop=\"url\" rel=\"noopener\">\n\t\t\t\t<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/12\/FME-32-W-FME-32-C-Beleuchtet-292x300.jpg\" alt=\"FME 32 W + FME 32 C (Beleuchtet)\" itemprop=\"image\" height=\"300\" width=\"292\" title=\"FME 32 W + FME 32 C (Beleuchtet)\" onerror=\"this.style.display='none'\"  \/>\n\t\t\t\t<\/a>\n\t<p>Image shows: FME 32 W and FME 32 C (photos from the test lab)<\/p>\n\t\n\t<ul>\n<li><strong>Type of construction:<\/strong><br \/>19&#8243; plug-in card 6U, 20M<br \/>\n<hr \/>\n<\/li>\n<li><strong>Weight:<\/strong><br \/>approx. 600g<br \/>\n<hr \/>\n<\/li>\n<li><a href=\"https:\/\/www.unitro.de\/wp\/en\/service-2\/emc-values\/\" target=\"_blank\" rel=\"noopener\"><strong>Climatic conditions:<\/strong><\/a><br \/><a href=\"https:\/\/www.unitro.de\/wp\/en\/service-2\/emc-values\/\" target=\"_blank\" rel=\"noopener\">in accordance with\u00a0UNITRO-PSC-Standard<\/a><br \/>\n<hr \/>\n<\/li>\n<li><strong>Connection:<\/strong><br \/>male multiple connector: <br \/>1x 48-pin E\u00a0 1x 96-pin C<br \/>\n<hr \/>\n<\/li>\n<li><strong>Function buttons:<\/strong><br \/>flashing acknowledge button<br \/>\n<hr \/>\n<\/li>\n<li><strong>Supply voltages:<\/strong><br \/>depending on the power supply card<br \/>24V DC \u00b1 10%<br \/>60V DC \u00b1 10%<br \/>110V DC \u00b1 10%<br \/>220V DC \u00b1 10%<br \/>230V AC \u00b1 10%<br \/>voltage-adapted<br \/>\n<hr \/>\n<\/li>\n<li><strong>Inputs:<\/strong><br \/>32 binary inputs, signal voltage:<br \/>24V DC<br \/>60V DC<br \/>200V DC<br \/>110V DC<br \/>voltage-adapted<br \/>voltage tolerance \u00b110%<br \/>\n<hr \/>\n<\/li>\n<li><strong>Time:<\/strong><br \/>millisecond time synchronization<br \/>\n<hr \/>\n<\/li>\n<li><strong>LED-display:<\/strong><br \/><strong>32 light field displays 10 x 32mm<\/strong> <br \/>selectable colors (red\/green\/yellow\/blue\/white) <br \/>with ex-changeable marking strips, flashing function <br \/>in accordance with DIN 19235<\/li>\n<\/ul>\n\t<ul>\n<li><strong>Decoupling:<\/strong><br \/>galvanic isolation of inputs via optocoupler<br \/>\n<hr \/>\n<\/li>\n<li><strong>Switch-on delay:<\/strong><br \/>up to 20sec<br \/>\n<hr \/>\n<\/li>\n<li><strong>Debounce time:<\/strong><br \/>up to 20ms<br \/>\n<hr \/>\n<\/li>\n<li><strong>Contact Selection:<\/strong><br \/>quiescent \/ operating current<br \/>\n<hr \/>\n<\/li>\n<li><strong>Interfaces:<\/strong><br \/>1x USB (for programming using an external PC)<br \/>1x RS485, 2x RS 232 ports (e.g. for printer)\u00a0<br \/>1x LON FTX,\u00a0<br \/><strong>16x Relay Outputs<\/strong> change-over max. 125V 0,4A<br \/>\n<hr \/>\n<\/li>\n<li><strong>Function:<\/strong><br \/>millisecond resolution and real-time mapping for SISSYpro first-value annunciator system with\u00a0programmable signal conditioning for the event detection with acknowledgment via integrated front button and remote acknowledgeable by the headquarters (SISSYpro),<br \/><strong>dead-man timer<\/strong> and watchdog for automatic reboot,<br \/>message transmission to the control center<br \/>\n<hr \/>\n<\/li>\n<li><strong>Parameterization:<\/strong><br \/>via integrated MINI USB interface or assumption of parameter data sets from the central SISSYpro with fail-safe storage in EEPROM<br \/>\n<hr \/>\n<\/li>\n<li><a href=\"https:\/\/www.unitro.de\/wp\/en\/service-2\/emc-values\/\" target=\"_blank\" rel=\"noopener\"><strong>Leakage distances and clearances:<\/strong><\/a><br \/><a href=\"https:\/\/www.unitro.de\/wp\/en\/service-2\/emc-values\/\" target=\"_blank\" rel=\"noopener\">in accordance with UNITRO-PSC-Standard<\/a><br \/>\n<hr \/>\n<\/li>\n<li><a href=\"https:\/\/www.unitro.de\/wp\/en\/service-2\/emc-values\/\" target=\"_blank\" rel=\"noopener\"><strong>EMC, immunity to interference:<\/strong><\/a><br \/><a href=\"https:\/\/www.unitro.de\/wp\/en\/service-2\/emc-values\/\" target=\"_blank\" rel=\"noopener\">UNITRO-PSC-Standard, <\/a><br \/><a href=\"https:\/\/www.unitro.de\/wp\/en\/service-2\/emc-values\/\" target=\"_blank\" rel=\"noopener\">immunity higher degrees of severity according to the actual generic standards DIN EN 61000<\/a><\/li>\n<\/ul>\n\t<p>subject to change<\/p>\n\n","protected":false},"excerpt":{"rendered":"<p>FME 32 W<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":2709,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-2196","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>FME 32 W, 19&quot; input card for ZFM - UNITRO - Fleischmann St\u00f6rmeldesysteme<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.unitro.de\/en\/products\/scada-systems\/condition-facility-monitoring\/fme-32-w-19-input-card-for-zfm\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"FME 32 W, 19&quot; input card for ZFM - UNITRO - Fleischmann St\u00f6rmeldesysteme\" \/>\n<meta property=\"og:description\" content=\"FME 32 W\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.unitro.de\/en\/products\/scada-systems\/condition-facility-monitoring\/fme-32-w-19-input-card-for-zfm\/\" \/>\n<meta property=\"og:site_name\" content=\"UNITRO - Fleischmann St\u00f6rmeldesysteme\" \/>\n<meta property=\"article:modified_time\" content=\"2021-02-16T16:59:33+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/05\/evu-standard-logo-2017-300x283.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/products\\\/scada-systems\\\/condition-facility-monitoring\\\/fme-32-w-19-input-card-for-zfm\\\/\",\"url\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/products\\\/scada-systems\\\/condition-facility-monitoring\\\/fme-32-w-19-input-card-for-zfm\\\/\",\"name\":\"FME 32 W, 19\\\" input card for ZFM - UNITRO - Fleischmann St\u00f6rmeldesysteme\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/products\\\/scada-systems\\\/condition-facility-monitoring\\\/fme-32-w-19-input-card-for-zfm\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/products\\\/scada-systems\\\/condition-facility-monitoring\\\/fme-32-w-19-input-card-for-zfm\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.unitro.de\\\/wp-content\\\/uploads\\\/2017\\\/05\\\/evu-standard-logo-2017-300x283.jpg\",\"datePublished\":\"2017-07-11T15:03:19+00:00\",\"dateModified\":\"2021-02-16T16:59:33+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/products\\\/scada-systems\\\/condition-facility-monitoring\\\/fme-32-w-19-input-card-for-zfm\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.unitro.de\\\/en\\\/products\\\/scada-systems\\\/condition-facility-monitoring\\\/fme-32-w-19-input-card-for-zfm\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/products\\\/scada-systems\\\/condition-facility-monitoring\\\/fme-32-w-19-input-card-for-zfm\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.unitro.de\\\/wp-content\\\/uploads\\\/2017\\\/05\\\/evu-standard-logo-2017-300x283.jpg\",\"contentUrl\":\"https:\\\/\\\/www.unitro.de\\\/wp-content\\\/uploads\\\/2017\\\/05\\\/evu-standard-logo-2017-300x283.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/products\\\/scada-systems\\\/condition-facility-monitoring\\\/fme-32-w-19-input-card-for-zfm\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/products\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"SCADA systems\",\"item\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/products\\\/scada-systems\\\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Condition + Facility &#8211; Monitoring\",\"item\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/products\\\/scada-systems\\\/condition-facility-monitoring\\\/\"},{\"@type\":\"ListItem\",\"position\":5,\"name\":\"FME 32 W, 19&#8243; input card for ZFM\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/\",\"name\":\"UNITRO - Fleischmann St\u00f6rmeldesysteme\",\"description\":\"since 1977 the power to control\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/#organization\",\"name\":\"UNITRO - Fleischmann St\u00f6rmeldesysteme\",\"url\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.unitro.de\\\/wp-content\\\/uploads\\\/2017\\\/05\\\/unitro-logo.png\",\"contentUrl\":\"https:\\\/\\\/www.unitro.de\\\/wp-content\\\/uploads\\\/2017\\\/05\\\/unitro-logo.png\",\"width\":320,\"height\":100,\"caption\":\"UNITRO - Fleischmann St\u00f6rmeldesysteme\"},\"image\":{\"@id\":\"https:\\\/\\\/www.unitro.de\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCJxURw1A7tEDsKUf81SRwnQ\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"FME 32 W, 19\" input card for ZFM - UNITRO - Fleischmann St\u00f6rmeldesysteme","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.unitro.de\/en\/products\/scada-systems\/condition-facility-monitoring\/fme-32-w-19-input-card-for-zfm\/","og_locale":"en_US","og_type":"article","og_title":"FME 32 W, 19\" input card for ZFM - UNITRO - Fleischmann St\u00f6rmeldesysteme","og_description":"FME 32 W","og_url":"https:\/\/www.unitro.de\/en\/products\/scada-systems\/condition-facility-monitoring\/fme-32-w-19-input-card-for-zfm\/","og_site_name":"UNITRO - Fleischmann St\u00f6rmeldesysteme","article_modified_time":"2021-02-16T16:59:33+00:00","og_image":[{"url":"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/05\/evu-standard-logo-2017-300x283.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.unitro.de\/en\/products\/scada-systems\/condition-facility-monitoring\/fme-32-w-19-input-card-for-zfm\/","url":"https:\/\/www.unitro.de\/en\/products\/scada-systems\/condition-facility-monitoring\/fme-32-w-19-input-card-for-zfm\/","name":"FME 32 W, 19\" input card for ZFM - UNITRO - Fleischmann St\u00f6rmeldesysteme","isPartOf":{"@id":"https:\/\/www.unitro.de\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.unitro.de\/en\/products\/scada-systems\/condition-facility-monitoring\/fme-32-w-19-input-card-for-zfm\/#primaryimage"},"image":{"@id":"https:\/\/www.unitro.de\/en\/products\/scada-systems\/condition-facility-monitoring\/fme-32-w-19-input-card-for-zfm\/#primaryimage"},"thumbnailUrl":"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/05\/evu-standard-logo-2017-300x283.jpg","datePublished":"2017-07-11T15:03:19+00:00","dateModified":"2021-02-16T16:59:33+00:00","breadcrumb":{"@id":"https:\/\/www.unitro.de\/en\/products\/scada-systems\/condition-facility-monitoring\/fme-32-w-19-input-card-for-zfm\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.unitro.de\/en\/products\/scada-systems\/condition-facility-monitoring\/fme-32-w-19-input-card-for-zfm\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.unitro.de\/en\/products\/scada-systems\/condition-facility-monitoring\/fme-32-w-19-input-card-for-zfm\/#primaryimage","url":"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/05\/evu-standard-logo-2017-300x283.jpg","contentUrl":"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/05\/evu-standard-logo-2017-300x283.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/www.unitro.de\/en\/products\/scada-systems\/condition-facility-monitoring\/fme-32-w-19-input-card-for-zfm\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/www.unitro.de\/en\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/www.unitro.de\/en\/products\/"},{"@type":"ListItem","position":3,"name":"SCADA systems","item":"https:\/\/www.unitro.de\/en\/products\/scada-systems\/"},{"@type":"ListItem","position":4,"name":"Condition + Facility &#8211; Monitoring","item":"https:\/\/www.unitro.de\/en\/products\/scada-systems\/condition-facility-monitoring\/"},{"@type":"ListItem","position":5,"name":"FME 32 W, 19&#8243; input card for ZFM"}]},{"@type":"WebSite","@id":"https:\/\/www.unitro.de\/en\/#website","url":"https:\/\/www.unitro.de\/en\/","name":"UNITRO - Fleischmann St\u00f6rmeldesysteme","description":"since 1977 the power to control","publisher":{"@id":"https:\/\/www.unitro.de\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.unitro.de\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.unitro.de\/en\/#organization","name":"UNITRO - Fleischmann St\u00f6rmeldesysteme","url":"https:\/\/www.unitro.de\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.unitro.de\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/05\/unitro-logo.png","contentUrl":"https:\/\/www.unitro.de\/wp-content\/uploads\/2017\/05\/unitro-logo.png","width":320,"height":100,"caption":"UNITRO - Fleischmann St\u00f6rmeldesysteme"},"image":{"@id":"https:\/\/www.unitro.de\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.youtube.com\/channel\/UCJxURw1A7tEDsKUf81SRwnQ"]}]}},"_links":{"self":[{"href":"https:\/\/www.unitro.de\/en\/wp-json\/wp\/v2\/pages\/2196","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.unitro.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.unitro.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.unitro.de\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.unitro.de\/en\/wp-json\/wp\/v2\/comments?post=2196"}],"version-history":[{"count":0,"href":"https:\/\/www.unitro.de\/en\/wp-json\/wp\/v2\/pages\/2196\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.unitro.de\/en\/wp-json\/wp\/v2\/pages\/2709"}],"wp:attachment":[{"href":"https:\/\/www.unitro.de\/en\/wp-json\/wp\/v2\/media?parent=2196"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}